C4-3-033-R400
Dimensions (W x H x D)125 x 142 x 280 mm, 555 mm with measuring sensor
Length300 mm measuring sensor
Weight1.580 kg
Power supplylithium ion batteries (operating time > 12 hours)
Sensitivity3 g/y C4-FN /year
Response time< 1 sec T90
Storage temperature-10 to +60 °C
Detection limit3 ppm C4-FN
Operating temperature0 to +50 °C
Measuring principleNon-dispersive infrared sensor (NDIR)
Indicationgraphic display + acoustic signal
Resolution1 ppm
Accuracy≤ 50: ≤ 2 ppm
Accuracy50 – 100: ≤ 2 ppm
Accuracy100 – 1000: ≤ 2 % of measuring range
Indication unitppm, g/y, cc/s
Measuring range0 – 1,000 ppm C4-FN
C4-3-039R-R201 MultiAnalyser
Dimensions (W x H x D)538 x 269 x 406 mm
Weight25 kg
Inlet pressure pe0.2 - 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90 % relative moisture, non condensing
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring time≤ 7 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle of
sensor in CO₂ or N₂
Non-dispersive infrared
sensor (NDIR)
Measuring range sensor
in CO₂ or N₂
0 - 10 mol %
Measuring accuracy sensor
in CO₂ or N₂
≤ 0.1 mol % at < 7%
Measuring accuracy sensor
in CO₂ or N₂
≤ 0.2 mol % at ≥ 7%
Measuring principle
of moisture sensor
Electronic dew point measurement (capacitive)
Measuring range of
moisture sensor
-60 to +20 °C
Measuring accuracy
of moisture sensor
≤ ± 2 °C (at > -40 °C)
Measuring accuracy
of moisture sensor
≤ ± 3 °C (at < -40 °C)

C4-3-039R-R301 MultiAnalyser

Dimensions (W x H x D)538 x 269 x 406 mm
Weight25 kg
Inlet pressure pe0.2 - 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90 % relative moisture, non condensing
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring time≤ 7 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle of
sensor in CO₂ or N₂
Non-dispersive infrared sensor (NDIR)
Measuring range sensor
in CO₂ or N₂
0 - 10 mol %
Measuring accuracy sensor
in CO₂ or N₂
≤ 0.1 mol % at < 7%
Measuring accuracy sensor
in CO₂ or N₂
≤ 0.2 mol % at ≥ 7%
Measuring principle
of moisture sensor
Electronic dew point measurement (capacitive)
Measuring range of
moisture sensor
-60 to +20 °C
Measuring accuracy
of moisture sensor
≤ ± 2 °C (at > -40 °C)
Measuring accuracy
of moisture sensor
≤ ± 3 °C (at < -40 °C)
Measuring principle O₂ sensorOptical measuring principle
Measuring range O₂ sensor0 - 25 mol %
Measuring accuracy O₂ sensor≤ ± 0.3 mol % (to 12%)**
Measuring accuracy O₂ sensor≤ ± 0.5 mol % (to 25%)***

C4-3-039R-R402 MultiAnalyser

Dimensions (W x H x D)538 x 269 x 406 mm
Weight25 kg
Inlet pressure pe0.2 - 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90 % relative moisture, non condensing
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring time≤ 7 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle of
sensor in CO₂ or N₂
Non-dispersive infrared sensor (NDIR)
Measuring range sensor in
CO₂ or N₂
0 - 10 mol %
Measuring accuracy sensor
in CO₂ or N₂
≤ 0.1 mol % at < 7%
Measuring accuracy sensor
in CO₂ or N₂
≤ 0.2 mol % at ≥ 7%
Measuring principle of
moisture sensor
Electronic dew point measurement (capacitive)
Measuring range of moisture
sensor
-60 to +20 °C
Measuring accuracy of moisture
sensor
≤ ± 2 °C (at > -40 °C)
Measuring accuracy of moisture
sensor
≤ ± 3 °C (at < -40 °C)
Measuring principle O₂ sensorOptical measuring principle
Measuring range O₂ sensor0 - 25 mol %
Measuring accuracy O₂ sensor≤ ± 0.3 mol % (to 12%)**
Measuring accuracy O₂ sensor≤ ± 0.5 mol % (to 25%)***
Measuring principle CO₂ sensorNon-dispersive infrared sensor (NDIR)
Measuring range CO₂ sensor0 - 100 mol %
Measuring accuracy CO₂ sensor≤ ± 2 mol %
Measuring principle CO sensorElectrochemical reaction
Measuring range of CO sensor0 - 500 ppm
Measuring accuracy of CO sensor≤ ± 2 % of measuring range

C4-3-039R-R407 MultiAnalyser

Dimensions (W x H x D)538 x 269 x 406 mm
Weight25 kg
Inlet pressure pe0.2 - 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90 % relative moisture, non condensing
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring time≤ 7 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle of
sensor in CO₂ or N₂
Non-dispersive infrared sensor (NDIR)
Measuring range sensor
in CO₂ or N₂
0 - 10 mol %
Measuring accuracy sensor
in CO₂ or N₂
≤ 0.1 mol % at < 7%
Measuring accuracy sensor
in CO₂ or N₂
≤ 0.2 mol % at ≥ 7%
Measuring principle of
moisture sensor
Electronic dew point measurement (capacitive)
Measuring range of moisture
sensor
-60 to +20 °C
Measuring accuracy of
moisture sensor
≤ ± 2 °C (at > -40 °C)
Measuring accuracy of
moisture sensor
≤ ± 3 °C (at < -40 °C)
Measuring principle O₂ sensorOptical measuring principle
Measuring range O₂ sensor0 - 25 mol %
Measuring accuracy O₂ sensor≤ ± 0.3 mol % (to 12%)**
Measuring accuracy O₂ sensor≤ ± 0.5 mol % (to 25%)***
Measuring principle
concentration CO sensor
Electrochemical reaction
Measuring range of CO sensor0 - 500 ppm
Measuring accuracy
concentration CO sensor
≤ ± 2 % of measuring range

C4-3-039R-R501 MultiAnalyser

Dimensions (W x H x D)538 x 269 x 406 mm
Weight25 kg
Inlet pressure pe0.2 - 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90 % relative moisture, non condensing
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured values
to be stored
500
InterfaceUSB / LAN / WiFi
Measuring time≤ 7 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle of sensor
in CO₂ or N₂
Non-dispersive infrared sensor (NDIR) (C4-FN)
Measuring range sensor
in CO₂ or N₂
0 - 10 mol %
Measuring accuracy sensor
in CO₂ or N₂
≤ 0.1 mol % at < 7%
Measuring accuracy sensor
in CO₂ or N₂
≤ 0.2 mol % at ≥ 7%
Measuring principle of
moisture sensor
Electronic dew point measurement (capacitive)
Measuring range of moisture
sensor
-60 to +20 °C
Measuring accuracy of
moisture sensor
≤ ± 2 °C (at > -40 °C)
Measuring accuracy of
moisture sensor
≤ ± 3 °C (at < -40 °C)
Measuring principle O₂ sensorOptical measuring principle
Measuring range O₂ sensor0 - 25 mol %
Measuring accuracy O₂ sensor≤ ± 0.3 mol % (to 12%)**
Measuring accuracy O₂ sensor≤ ± 0.5 mol % (to 25%)***
Measuring principle CO₂ sensorNon-dispersive infrared sensor (NDIR)
Measuring range CO₂ sensor0 - 100 mol %
Measuring accuracy CO₂ sensor≤ ± 2 mol %
Measuring principle
concentration CO sensor
Electrochemical reaction
Measuring range of CO sensor0 - 500 ppm
Measuring accuracy
concentration CO sensor
≤ ± 2 % of measuring range

C4-3-558-R001 C Precision gauge with hose

Dimensions (W x H x D) 420 x 180 x 500 mm
Weight 4 kg

CA-3-035R-R201 MirrorAnalyser

Dimensions (W x H x D)625 x 297 x 500 mm
Weight27,50 kg
Inlet pressure pe0,2 - 35 bar
Ambient moisturemax. 90% relative humidity, non-condensing during operation
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring time≤ 10 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle
of moisture sensor
Dew point mirror (physical measuring principle)
Measuring range of
moisture sensor
-50 to +20 °C
Measuring accuracy
of moisture sensor
≤ ± 0,5 °C
Measuring principle O₂ sensorOptical measuring principle
Measuring range O₂ sensor0 - 25 mol %
Measuring accuracy O₂ sensor≤ ± 0,3 mol % (to 12%)**
Measuring accuracy O₂ sensor≤ ± 0,5 mol % (to 25%)***

CA-3-039R-R201 MultiAnalyser

Dimensions (W x H x D)538 x 269 x 406 mm
Weight25 kg
Inlet pressure pe0.2 - 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90 % relative moisture, non condensing
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring timemax. 7 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle
of moisture sensor
Electronic dew point measurement (capacitive)
Measuring range of
moisture sensor
-60 to +20 °C
Measuring accuracy
of moisture sensor
≤ ± 2 °C (at > -40 °C)
Measuring accuracy
of moisture sensor
≤ ± 3 °C (at < -40 °C) (CO₂)
Measuring principle O₂ sensorOptical measuring principle
Measuring range O₂ sensor0 - 25 mol %
Measuring accuracy O₂ sensor≤ ± 0.3 mol % (to 12%)**
Measuring accuracy O₂ sensor≤ ± 0.5 mol % (to 25%)***

CA-3-039R-R401 MultiAnalyser

Dimensions (W x H x D)538 x 269 x 406 mm
Weight25 kg
Inlet pressure pe0.2 - 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90 % relative moisture, non condensing
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring timemax. 7 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle
of moisture sensor
Electronic dew point measurement (capacitive)
Measuring range of
moisture sensor
-60 to +20 °C
Measuring accuracy
of moisture sensor
≤ ± 2 °C (at > -40 °C)
Measuring accuracy
of moisture sensor
≤ ± 3 °C (at < -40 °C)
Measuring principle
O₂ sensor
Optical measuring principle
Measuring range O₂ sensor0 - 25 mol %
Measuring accuracy O₂ sensor≤ ± 0.3 mol % (to 12%)**
Measuring accuracy O₂ sensor≤ ± 0.5 mol % (to 25%)***
Measuring principle
concentration NO₂ sensor
Electrochemical reaction
Measuring range
concentration NO₂ sensor
0 - 20 ppm NO₂
Measuring accuracy
concentration NO₂ sensor
≤ ± 2 % of measuring range
Measuring principle of CO sensorElectrochemical reaction
Measuring range of CO sensor0 - 500 ppm
Measuring accuracy of CO sensor± 2 %

CO2-3-039R-R401 MultiAnalyser

Dimensions (W x H x D)538 x 269 x 406 mm
Weight25 kg
Inlet pressure pe0.2 – 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90% relative moisture, non condensing
Operating voltage85 – 264 V AC
Frequency47 – 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring timemax. 7 min (calculated by the system)
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle of
moisture sensor
Electronic dew point measurement (capacitive)
Measuring range of
moisture sensor
-50 to +20 °C
Measuring accuracy
of moisture sensor
≤ ±2 °C (at > -40 °C)
Measuring accuracy of
moisture sensor
≤ ±3 °C (at < -40 °C)
Measuring principle O₂ sensorElectrochemical reaction
Measuring range O₂ sensor0 – 25 mol %
Measuring accuracy O₂ sensor≤ ±0.3 mol % (to 12%)
Measuring accuracy O₂ sensor≤ ±0.5 mol % (to 25%)
Measuring principle CO₂ sensorNon-dispersive infrared sensor (NDIR)
Measuring range CO₂ sensor0 – 100 mol %
Measuring accuracy CO₂ sensor≤ ±2 mol %
Measuring principle
concentration CO sensor
Electrochemical reaction
Measuring range
concentration CO sensor
0 – 500 ppm
Measuring accuracy
concentration CO sensor
≤ ±2 % of measuring range
C4-3-039R-R101 MultiAnalyser
Dimensions (W x H x D)538 x 269 x 406 mm
Weight25 kg
Inlet pressure pe0.2 - 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90 % relative moisture, non condensing
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured values to be stored500
InterfaceUSB / LAN / WiFi
Measuring time≤ 7 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle of sensor in CO₂ or N₂Non-dispersive infrared sensor (NDIR)
Measuring range sensor in CO₂ or N₂0 - 10 mol %
Measuring accuracy sensor in CO₂ or N₂≤ 0.1 mol % at < 7%
Measuring accuracy sensor in CO₂ or N₂≤ 0.2 mol % at ≥ 7%
C4-3-039R-R202 MultiAnalyser
Dimensions (W x H x D)538 x 269 x 406 mm
Weight25 kg
Inlet pressure pe0.2 - 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90 % relative moisture, non condensing
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring time≤ 7 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle of
sensor in CO₂ or N₂
Non-dispersive infrared sensor (NDIR)
Measuring range sensor in
CO₂ or N₂
0 - 10 mol %
Measuring accuracy sensor
in CO₂ or N₂
≤ 0.1 mol % at < 7%
Measuring accuracy sensor
in CO₂ or N₂
≤ 0.2 mol % at ≥ 7%
Measuring principle O₂ sensorOptical measuring principle
Measuring range O₂ sensor0 - 25 mol %
Measuring accuracy O₂ sensor≤ ± 0.3 mol % (to 12%)**
Measuring accuracy O₂ sensor≤ ± 0.5 mol % (to 25%)***

C4-3-039R-R302 MultiAnalyser

Dimensions (W x H x D)538 x 269 x 406 mm
Weight25 kg
Inlet pressure pe0.2 - 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90 % relative moisture, non condensing
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring time≤ 7 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle
of sensor in CO2 or N2
Non-dispersive infrared sensor (NDIR)
Measuring range sensor
in CO2 or N2
0 - 10 mol %
Measuring accuracy sensor
in CO2 or N2
≤ 0.1 mol % at < 7%
Measuring accuracy sensor
in CO2 or N2
≤ 0.2 mol % at ≥ 7%
Measuring principle O2 sensorOptical measuring principle
Measuring range O2 sensor0 - 25 mol %
Measuring accuracy O2 sensor≤ ± 0.3 mol % (to 12%)**
Measuring accuracy O2 sensor≤ ± 0.5 mol % (to 25%)***
Measuring principle CO2 sensorNon-dispersive infrared sensor (NDIR)
Measuring range CO2 sensor0 - 100 mol %
Measuring accuracy CO2 sensor≤ ± 2 mol %

C4-3-039R-R401 MultiAnalyser

Dimensions (W x H x D)538 x 269 x 406 mm
Weight25 kg
Inlet pressure pe0.2 - 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90 % relative moisture, non condensing
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring time≤ 7 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle of
sensor in CO2 or N2
Non-dispersive infrared sensor (NDIR)
Measuring range sensor
in CO2 or N2
0 - 10 mol %
Measuring accuracy
sensor in CO2 or N2
≤ 0.1 mol % at < 7%
Measuring accuracy
sensor in CO2 or N2
≤ 0.2 mol % at ≥ 7%
Measuring principle of
moisture sensor
Electronic dew point measurement (capacitive)
Measuring range of
moisture sensor
-60 to +20 °C
Measuring accuracy
of moisture sensor
≤ ± 2 °C (at > -40 °C)
Measuring accuracy
of moisture sensor
≤ ± 3 °C (at < -40 °C)
Measuring principle O2 sensorOptical measuring principle
Measuring range O2 sensor0 - 25 mol %
Measuring accuracy O2 sensor≤ ± 0.3 mol % (to 12%)**
Measuring accuracy O2 sensor≤ ± 0.5 mol % (to 25%)***
Measuring principle of CO sensorElectrochemical reaction
Measuring accuracy
concentration CO sensor
0 - 500 ppm
Measuring accuracy
concentration CO sensor
≤ ± 2 % of measuring range

C4-3-039R-R405 MultiAnalyser

Dimensions (W x H x D)538 x 269 x 406 mm
Weight25 kg
Inlet pressure pe0.2 - 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90 % relative moisture, non condensing
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring time≤ 7 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle of
sensor in CO₂ or N₂
Non-dispersive infrared sensor (NDIR)
Measuring range sensor
in CO₂ or N₂
0 - 10 mol %
Measuring accuracy sensor
in CO₂ or N₂
≤ 0.1 mol % at < 7%
Measuring accuracy sensor
in CO₂ or N₂
≤ 0.2 mol % at ≥ 7%
Measuring principle of
moisture sensor
Electronic dew point measurement (capacitive)
Measuring range of moisture
sensor
-60 to +20 °C
Measuring accuracy of
moisture sensor
≤ ± 2 °C (at > -40 °C)
Measuring accuracy
of moisture sensor
≤ ± 3 °C (at < -40 °C)
Measuring principle
O₂ sensor
Optical measuring principle
Measuring range O₂ sensor0 - 25 mol %
Measuring accuracy O₂ sensor≤ ± 0.3 mol % (to 12%)**
Measuring accuracy O₂ sensor≤ ± 0.5 mol % (to 25%)***
Measuring principle
concentration CO sensor
Electrochemical reaction
Measuring range of CO sensor0 - 500 ppm
Measuring accuracy
concentration CO sensor
≤ ± 2 % of measuring range

C4-3-039R-R503 MultiAnalyser

Dimensions (W x H x D)538 x 269 x 406 mm
Weight25 kg
Inlet pressure pe0.2 - 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90 % relative moisture, non condensing
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring time≤ 7 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle
of sensor in CO₂ or N₂
Non-dispersive infrared sensor (NDIR)
Measuring range
sensor in CO₂ or N₂
0 - 10 mol %
Measuring accuracy
sensor in CO₂ or N₂
≤ 0.1 mol % at < 7%
Measuring accuracy
sensor in CO₂ or N₂
≤ 0.2 mol % at ≥ 7%
Measuring principle of
moisture sensor
Electronic dew point measurement (capacitive)
Measuring range of
moisture sensor
-60 to +20 °C
Measuring accuracy
of moisture sensor
≤ ± 2 °C (at > -40 °C)
Measuring accuracy
of moisture sensor
≤ ± 3 °C (at < -40 °C)
Measuring principle O₂ sensorOptical measuring principle
Measuring range O₂ sensor0 - 25 mol %
Measuring accuracy O₂ sensor≤ ± 0.3 mol % (to 12%)**
Measuring accuracy O₂ sensor≤ ± 0.5 mol % (to 25%)***
Measuring principle CO₂ sensorNon-dispersive infrared sensor (NDIR)
Measuring range CO₂ sensor0 - 100 mol %
Measuring accuracy CO₂ sensor≤ ± 2 mol %
Measuring principle
concentration CO sensor
Electrochemical reaction
Measuring range of CO sensor0 - 500 ppm
Measuring accuracy
concentration CO sensor
≤ ± 2 % of measuring range

CA-3-035R-R101 MirrorAnalyser

Dimensions (W x H x D)625 x 297 x 500 mm
Weight27,50 kg
Inlet pressure pe0,2 - 35 bar
Ambient moisturemax. 90% relative humidity, non-condensing during operation
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring time≤ 10 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle of
moisture sensor
Dew point mirror (physical measuring principle)
Measuring range of
moisture sensor
-50 to +20 °C
Measuring accuracy of
moisture sensor
≤ ± 0,5 °C

CA-3-035R-R301 MirrorAnalyser

Dimensions (W x H x D)625 x 297 x 500 mm
Weight27,50 kg
Inlet pressure pe0,2 - 35 bar
Ambient moisturemax. 90% relative humidity, non-condensing during operation
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring time≤ 10 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle
of moisture sensor
Dew point mirror (physical measuring principle)
Measuring range of
moisture sensor
-50 to +20 °C
Measuring accuracy
of moisture sensor
≤ ± 0,5 °C
Measuring principle O₂ sensorOptical measuring principle
Measuring range O₂ sensor0 - 25 mol %
Measuring accuracy O₂ sensor≤ ± 0,3 mol % (to 12%)**
Measuring accuracy O₂ sensor≤ ± 0,5 mol % (to 25%)***
Measuring principle
concentration NO₂ sensor
Electrochemical reaction
Measuring range
concentration NO₂ sensor
0 - 20 ppm NO₂
Measuring accuracy
concentration NO₂ sensor
≤ ± 2 % of measuring range

CA-3-039R-R301 MultiAnalyser

Dimensions (W x H x D)538 x 269 x 406 mm
Weight25 kg
Inlet pressure pe0.2 - 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90 % relative moisture, non condensing
Operating voltage85 - 264 V AC
Frequency47 - 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring timemax. 7 min variable calculated by the system
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle of
moisture sensor
Electronic dew point measurement (capacitive)
Measuring range of
moisture sensor
-60 to +20 °C
Measuring accuracy
of moisture sensor
≤ ± 2 °C (at > -40 °C)
Measuring accuracy
of moisture sensor
≤ ± 3 °C (at < -40 °C)
Measuring principle
O₂ sensor
Optical measuring principle
Measuring range O₂ sensor0 - 25 mol %
Measuring accuracy O₂ sensor≤ ± 0.3 mol % (to 12%)**
Measuring accuracy O₂ sensor≤ ± 0.5 mol % (to 12%)**
Measuring principle
concentration NO₂ sensor
Electrochemical reaction
Measuring range
concentration NO₂ sensor
0 - 20 ppm NO₂
Measuring accuracy
concentration NO₂ sensor
≤ ± 2 % of measuring range

CO2-3-039R-R301 MultiAnalyser

Weight25 kg
Inlet pressure pe0.2 – 35 bar
Operating temperature-10 to +50 °C
Ambient moisturemax. 90% relative moisture, non condensing
Operating voltage85 – 264 V AC
Frequency47 – 63 Hz
Number of max. measured
values to be stored
500
InterfaceUSB / LAN / WiFi
Measuring timemax. 7 min (calculated by system)
Protection classIP65 (device closed) / IP20 (device opened)
Measuring principle of
moisture sensor
Electronic dew point measurement (capacitive)
Measuring range of
moisture sensor
-50 to +20 °C
Measuring accuracy of
moisture sensor
≤ ±2 °C (at > -40 °C)
Measuring accuracy of
moisture sensor
≤ ±3 °C (at < -40 °C)
Measuring principle O₂ sensorElectrochemical reaction
Measuring range O₂ sensor0 – 25 mol %
Measuring accuracy O₂ sensor≤ ±0.3 mol % (to 12%)
Measuring accuracy O₂ sensor≤ ±0.5 mol % (to 25%)
Measuring principle CO₂ sensorNon-dispersive infrared sensor (NDIR)
Measuring range CO₂ sensor0 – 100 mol %
Measuring accuracy CO₂ sensor≤ ±2 mol %